Instructions on filling your new Hot Spring Hot Spot Hot Tub for the first time:
Starting up your new Hot Spring Hot Spot Series hot tub is not as overwhelming as it might seem. We realize you may see conflicting information, especially if you are getting tips and advice from the Internet. Itās important to remember that not all hot tubs are made to function in the same manner, so please call your salesperson if you have any questions about starting up your hot tub for the first time. If you have well water (private or community) we strongly recommend using a pre-filter attachment on your water hose to reduce and eliminate problematic minerals from entering your hot tub. Please take the time to read thru the following instructions before starting to fill your new spa and refer to the section below, Hot Tub Water Care Guide, for how to properly balance your new spaās water!
- Do not fill the spa with hot water, as tripping of the high-limit thermostat may result.
- DO NOT CONNECT POWER TO AN EMPTY SPA. Power to the spa automatically activates critical components within the spa, such as controls, heater, and other systems. If power is supplied to these components prior to the spa being filled, the components will be damaged, and this may result in a non-warranty component failure.
- Do not use your spa after filling until all of the steps listed below are completed.
- Before filling your spa for the first time, remove the equipment compartment door and check to ensure that the unions on either side of the pump(s) and heater are hand-tight.
- CLOSE ALL DRAINS, OPEN YOUR SPA FROG CHAMBER CAP and remove the filter compartment cover and filter. Fill your spa through the filter compartment (using the CleanScreenā¢ pre-filter that attaches to your garden hose if you are well water). The water level of your spa should be maintained at approximately one inch above the highest jet in the spa. Reinstall the filter. Your water level should be above the skimmer basket of the filter compartment. Water should be allowed to flow thru the Spa Frog chamber during the re-fill process.
IMPORTANT: Watkins Manufacturing Corporation does not recommend that the spa be filled with āsoftenedā water, as this may damage the spaās equipment.
- After the spa has been filled with water and the equipment compartment door is secured, power must be applied to the spa.
- FIRST activate power to the subpanel from the main house panel.
- NEXT open the door of the electrical subpanel and reset the GFCI breaker.
- FINALLY, close and secure the subpanel door.
- TO CHECK THE OPERATION OF THE JET SYSTEM and to purge any remaining air from the heating system, push the āJETSā button on the control panel three times (twice for TX and SX models) to run the jet pump(s) on high speed for one minute. Once the jet system is fully operational (as indicated by strong, non-surging jets), priming of the spa is complete. Turn off the jets by pressing the āJETSā button until all jets have turned off. If you do not feel a steady stream of water from your jets, refer to the instructions for priming the pump in the SPA TROUBLESHOOTING section in your Ownerās Manual.
- SET THE TEMPERATURE CONTROL to the desired temperature between 100Ā°F (38Ā°C) and 104Ā°F (40Ā°C), then place the spa cover on the spa and allow the water temperature to stabilize (this could take up to 24 hours). Make sure you secure the cover in place using the cover locks. Periodically check the spa water temperature. When the water temperature climbs above 90Ā°F (32Ā°C), you may begin balancing your hot tubās water. Please refer to our Hot Tub Water Care Guide for more detailed instructions on balancing your hot tubās water. The spa temperature is pre-programmed to reach 100F (39Ā°C), and will normally do so within 18 to 24 hours. You may raise the water temperature to your desired degree. After a few hours, the water temperature will remain within 3ĖF (1.5Ā°C) of your selected temperature.
Hot Tub Water Care Guide for Hot Spring Hot Spot Spa Customers:
Balancing your hot tub water should not begin until your spa is heated to the desired temperature. As your water heats up, pH and Alkaline levels may change, so itās important not to rush through the startup process. Once your hot tub has achieved the desired temperature, you may test the spa water for the first time with your test strips. Simply dip the test strip in the water and then pull the strip out of the water and line up the colored pads on the strip to the back of the bottle. Make a note of what your readings are before adding any chemicals to the water. Ideally, your spaās pH should read between 7.2-7.6 ppm and the Alkaline should be between 80-120 ppm.
- Metal Gon: If you are on a well (private or community) we recommend using a full bottle of Metal Gon to keep any problematic minerals in a liquid state, thus preventing unwanted buildup in your hot tubās plumbing lines and mechanical equipment. Turn on you spaās jet pump(s) and pour the full bottle of Metal Gon in your spaās filter compartment. Allow the jets to run for 30-45 minutes and then turn the jets off. You need to allow the Metal Gon to circulate through the spaās plumbing lines over the next 8-12 hours. We do not recommend adding anything else to your spa water until 8-12 hours has passed. Itās important not to rush this step.
- Stain and Scale: If you are on city water, instead of using Metal Gon, we recommend using one third of the bottle (3-4 oz) of Stain and Scale. Run your spaās jet pump(s) for 30 minutes and then allow the spa to circulate for the next 8-12 hours. Proceed to next step.
- pH and Alkalinity: If you need to make any adjustment to the pH and Alkaline, you may do so at this time using pH increaser or decreaser or Alkaline increaser. ***There is no such thing as Alkalinity decreaser. If your Alkalinity is high, you may use a tablespoon of Muriatic Acid to reduce the Alkaline reading or you may use pH decreaser, which is also a dry acid and will reduce the overall Alkalinity. Make a note of whatever modifications you make so you will have a good idea of what to expect the next time you fill your hot tub and proceed to the next step.
- Jump Start: Add the pre-measured packet called “Jump Start” which is a combination of oxidizer and sodium di-chlor that will create the correct sanitizer balance for start up.
- Mineral & Smart-Chlor Cartridge: Unscrew the SpaFrog chamber lid. Dial the lid on the Spa Frog Mineral Cartridge to a “6” and then insert the Spa Frog Mineral Cartridge (Blue Cartridge) into top position of the Spa Frog chamber. Dial the lid on the Smart-Chlor Cartridge to your desired level (on a scale of “0-6” based on expected use) and insert the Smart-Chlor Cartridge (Grey Cartridge) into the bottom position of the Spa Frog chamber.
You are now ready to use your new hot tub!!! Within the first 48 hours, you will want to rinse your hot tub’s filter for the first time.
A few things to rememberā¦
After each use: we recommend adding one tablespoon per person of the Oxidizer after each use while running a āclean cycleā. This will help keep your water fresh and clear by removing organics.
Weekly: If using the SmartChlor system, use the SpaFrog test strips to monitor your spas ph, alkalinity and SmartChlor levels. Make adjustments as needed. With frequent hot tub use, you can add 1-2 tablespoons of granular chlorine weekly to keep up with frequently, daily use.
Monthly: Clean your filter, even if it looks clean, at least once a month. This will remove all organic and mineral build up and will help keep your water fresh and clean. Just rinse it with a hose on a high power nozzle to release all undesirables. Replace your Smart-Chlor cartridge monthly or more frequently depending on use.
Quarterly: Replace your Spa Frog Mineral Cartridge. These have a finite lifespan of four months and should be refreshed 3 times a year. Clean your spa cover to remove any mildew and apply a protective coat of CoverShield to the top of the cover.
Drain and refill your spa as needed. For most customers, this is once every four months.
***IF YOU HAVE AN OZONATOR installed on your spa, it is not unusual for your āFCLā or Free Chlorine levels to read at ā0ā on 5-way test strip if you are also using a 5-way test strip. This is normal and do not be alarmed. Ozone system effectively burn out the remaining free chlorine, so you will be left with clean, fresh water (and none of the heavy chlorine smells that you normally see in spas with no ozone system).